20kg
per m˛
is the only grade of lead
recommended by the Building Code of Australia.
20kg
per m˛
is suitable for exposed flashings.
IMPORTANT INSTALLATION INSTRUCTIONS.
SINGLE LAID SHEETS of LEAD, SHOULD NOT EXCEED 1500mm in
LENGTH or 1.5m˛ in AREA.
Refer to AS 2904:1995 - DPC & Flashings and to the
Building Code of Australia for further installation guidelines.
Failure to install the product correctly will increase
the chances of stress fractures due to material expansion during
temperature changes.
FACTS you will want to
know.
Copperised Lead Sheet for Residential Applications.
Suitable for damp-proof
course or exposed flashings.
Premium Quality 99.8%
Pure Lead.
Residual traces of other
minerals, including Copper, actually help to make the Lead more
malleable (workable).
COMPLIES with;
AS 1804-1976 Soft Lead
Sheet and Strip, AND
AS 2904:1995—Damp-proof
Courses and Flashings incl. Amendment 1—1998
THROUGH;
CURRENT CERTIFICATION
in the implementation and
maintenance of a
QUALITY MANAGEMENT SYSTEM
under ISO 9002 in 1994,
REVISED in 2003 according